CLASSVIEW INSTALLATION AND OPERATINS MANUAL
29
Appendix C. Factory default settings
Screen Blank time Interval
43 (Rate=10.9chars/sec, delay = 500 millisec.)
Appendix D. Dip switch description
DIP SWITCH
POSITION
DIP SWITCH
VALUE
A Unit's address is determined from the settings of the dip switch upon power
up. The dip switch forms a standard binary number with up being a "one"
and down being a "zero". Each position has a value corresponding to it.
From left to right the values are 128, 64, 32, 16, 8, 4, 2, and 1. When the dip
switch is up add the values of the position to form the address value.
The most common values and positions are:
1 (8 up – shown above)
2 (7 up)
3 (7, 8 up)
4 (6 up)
5 (6, 8 up)
6 (6, 7 up)
7 (6, 7, 8 up)
8 (5 up)
9 (5, 8 up)
10 (5, 7 up)